Call Us 1-877-306-7255
Power To Keep You On The Go! 
Our quality line of rechargeable wheelchair batteries are powerful, clean and maintenance free.
Our Products

Centennial Sealed GEL - 6 volt
BCI GROUP SIZE CENTENNIAL PART No. AH @ 20HR RC minutes @ 25 amps CCA CA / MCA TERM TYPE LENGTH WIDTH HEIGHT
GC2 CBGC2-GEL 180 375 --- --- U 10 1/4 7 1/8 10 7/8
                   
Centennial Sealed GEL - 12 volt
BCI GROUP SIZE CENTENNIAL PART No. AH @ 20HR RC minutes @ 25 amps CCA CA / MCA TERM TYPE LENGTH WIDTH HEIGHT
U1 CBU1-GEL 32 47 215 310 L 7 3/4 5 3/16 7 1/4
22NF CB22NF-GEL 51 87 245 350 U 9 3/8 5 1/2 9 1/4
24 CB24-GEL 74 140 410 575 MT 10 7/8 6 3/4 9 7/8
27 CB27-GEL 86 170 505 700 MT, F 12 3/4 6 3/4 9 7/8
31 CB31-GEL 98 195 550 760 DT 12 15/16 6 3/4 9 3/8
4D CB4D-GEL 183 395 970 1350 A 20 3/4 8 1/2 10
8D CB8D-GEL 225 500 1150 1615 A 20 3/4 11 10
CCA - Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0 degrees farenheit at a voltage above 1.2 v/cell
CA - Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell
MCA - Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80 degrees farenheit and maintain a voltage above 1.75 v/cell.
AH - Ampere Hour Capacity - A unit of measurement for electron flow or current through an electrical circuit for a certain period of time. The 20 hour rate is a BCI sanctioned rating expressing ampere hours required to achieve an end voltage of 1.75 v/cell at 80 degrees farenheit, and represents the batteries maximum capacity. The 5 hour rate is based on IEC (International Electrotechnical Commission) temperature standard of 30 degrees celsius (86 degrees farenheit)

The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development.
We reserve the right to change design, specifications, or pricing at any time without notice and without incurring obligation.





Centennial Sealed AGM - 6 volt
BCI GROUP SIZE CENTENNIAL PART No. VOLTAGE AH @ 20HR AH @ 10HR LENGTH WIDTH HEIGHT TERM HEIGHT WEIGHT(LBS)
27 CB6-200 6 VOLTS 200 180 12.05 6.61" 8.74" 8.94" 64.00
GC2 CB6-224 6 VOLTS 224 205 10.24" 7.09" 9.72" 9.92" 69.44
Centennial Sealed AGM - 12 volt
BCI GROUP SIZE CENTENNIAL PART No. VOLTAGE AH @ 20HR AH @ 10HR LENGTH (IN) WIDTH (IN) HEIGHT (IN) TERM HEIGHT (IN) WEIGHT (LBS)
U1 CB12-35 12 VOLT 36.4 35.0 7.68 5.12 6.26 7.09 22.49
22NF CB12-55 12 VOLT 56.6 55.0 9.02 5.43 8.07 8.90 39.69
24 CB12-85 12 VOLT 85.0 80.0 10.24 6.65 8.27 8.46 54.67
27 CB12-105 12 VOLT 105.0 100.0 12.07 6.63 8.27 8.46 66.14
31 CB12-115 12 VOLT 115.0 110.0 12.91 6.77 8.54 8.74 73.19
4D CB12-210 12 VOLT 210.0 195.0 20.87 8.23 8.43 9.41 134.49
8D CB12-260 12 VOLT 270.0 260.0 20.47 10.55 8.66 9.65 169.75
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80 degrees farenheit and maintain a voltage above 1.75 v/cell.
AH - Ampere Hour Capacity - A unit of measurement for electron flow or current through an electrical circuit for a certain period of time. The 20 hour rate is a BCI sanctioned rating expressing ampere hours required to achieve an end voltage of 1.75 v/cell at 80 degrees farenheit, and represents the batteries maximum capacity. The 5 hour rate is based on IEC (International Electrotechnical Commission) temperature standard of 30 degrees celsius (86 degrees farenheit)

The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development.
We reserve the right to change design, specifications, or pricing at any time without notice and without incurring obligation.





Centennial Sealed Mobility - AGM Technology
BCI GROUP SIZE CENTENNIAL PART No. AH @ 20HR RC minutes @ 25 amps CCA CA / MCA TERM TYPE LENGTH WIDTH HEIGHT
U1 CBM-33 33 83 --- --- L 7 3/4 5 13/16 7 3/8
22NF CBM-50 50 126 --- --- L 9 5 1/2 8 11/16
24 CBM-75 75 189 --- --- L 10 1/4 6 13/16 8 11/16
27 CBM-88 88 222 --- --- L 12 3/4 6 13/16 10
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80 degrees farenheit and maintain a voltage above 1.75 v/cell.
AH - Ampere Hour Capacity - A unit of measurement for electron flow or current through an electrical circuit for a certain period of time. The 20 hour rate is a BCI sanctioned rating expressing ampere hours required to achieve an end voltage of 1.75 v/cell at 80 degrees farenheit, and represents the batteries maximum capacity. The 5 hour rate is based on IEC (International Electrotechnical Commission) temperature standard of 30 degrees celsius (86 degrees farenheit)

The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development.
We reserve the right to change design, specifications, or pricing at any time without notice and without incurring obligation.