Call Us 1-877-306-7255
LTV / Commercial / Tractor 
When you need powerful starting ability, and dependable lasting power, Centennial Commercial batteries rise to the challenge. Centennial Commercial batteries are built tough to meet or exceed your most demanding requirements.

From commercial trucks to heavy duty equipment, we have the power for the long haul! We offer a complete line of heavy duty batteries to fit your application and get the job done. Available in low maintenance or completely maintenance free. NEVER ADD WATER!
Our Products
Light Truck and Van Series
BCI GROUP SIZE CENTENNIAL PART No. CCA RC minutes @ 25 amps CA / MCA HCA VOLTAGE LENGTH WIDTH HEIGHT
34/78 78DT-LTV 850 120 1065 1225 12 10 7/8 7 8
24 24LTV 800 120 1000 1150 12 10 13/16 6 13/16 8 13/16
24F 24FLTV 800 120 1000 1150 12 10 13/16 6 13/16 8 13/16
27 27LTV 800 160 1000 1150 12 12 1/16 6 13/16 8 7/8
27F 27FLTV 800 160 1000 1150 12 12 1/16 6 13/16 8 7/8
65 65LTV 850 160 1065 1225 12 11 7/8 7 1/2 7 5/8
78 78LTV 850 140 1065 1225 12 10 7/8 7 7 5/16
CCA - Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0° F at a voltage above 1.2 v/cell
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80° F and maintain a voltage above 1.75 v/cell.
CA - Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell
MCA - Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell
HCA - Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 80° F at a voltage above 1.2 v/cell

The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development.
We reserve the right to change design, specifications, or pricing at any time without notice and without incurring obligation.




12 Volt Severe Condition Series - Maintenance Free
BCI GROUP SIZE CENTENNIAL PART No. CCA RC minutes @ 25 amps CA / MCA HCA VOLTAGE LENGTH WIDTH HEIGHT
31AP C-31-10APMF 950 195 1190 1370 12 13 6 13/16 9 7/16
31STUD C-31-10STMF 950 195 1190 1370 12 13 6 13/16 9 7/16
31AP C-31-7APMF 750 180 940 1080 12 13 6 13/16 9 7/16
31STUD C-31-7STMF 750 180 940 1080 12 13 6 13/16 9 7/16
4D C-4DMF 1000 300 1250 1440 12 20 3/4 8 3/4 9 7/8
8D C-8DMF 1200 430 1500 1725 12 20 3/4 11 1/8 9 7/8
8D C-8DHMF 1350 440 1690 1945 12 20 3/4 11 1/8 9 7/8
CCA - Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0° F at a voltage above 1.2 v/cell
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80° F and maintain a voltage above 1.75 v/cell.
CA - Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell
MCA - Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell
HCA - Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 80° F at a voltage above 1.2 v/cell

The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development.
We reserve the right to change design, specifications, or pricing at any time without notice and without incurring obligation.




12 Volt Heavy Duty Commercial
BCI GROUP SIZE CENTENNIAL PART No. CCA RC minutes @ 25 amps CA / MCA HCA VOLTAGE LENGTH WIDTH HEIGHT
29NF C-29NF 420 100 525 605 12 13 5 /1/2 8 5/16
30H C-30H 800 170 1000 1150 12 13 1/2 6 13/16 9 1/4
31AP C-31-10AP 1000 200 1250 1440 12 13 6 13/16 9 7/16
31STUD C-31-10ST 1000 200 1250 1440 12 13 6 13/16 9 7/16
31AP C-31-9AP 930 190 1160 1340 12 13 6 13/16 9 7/16
31STUD C-31-9ST 930 190 1160 1340 12 13 6 13/16 9 7/16
31AP C-31-8AP 800 180 1000 1150 12 13 6 13/16 9 7/16
31STUD C-31-8ST 800 180 1000 1150 12 13 6 13/16 9 7/16
31AP C-31-7AP 700 160 875 1005 12 13 6 13/16 9 7/16
31STUD C-31-7ST 700 160 875 1005 12 13 6 13/16 9 7/16
4D C-4D 1100 325 1375 1580 12 20 3/4 8 3/4 9 7/8
50 C-50 600 108 750 860 12 13 1/2 5 10
53 C-53 350 85 440 505 12 13 4 11/16 8 1/4
8D C-8D 1200 350 1500 1725 12 20 3/4 11 1/8 9 7/8
8D C-8D-BT 1200 350 1500 1725 12 20 3/4 11 1/8 9 7/8
8D C-8DH 1400 390 1750 2010 12 20 3/4 11 1/8 9 7/8
CCA - Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0° F at a voltage above 1.2 v/cell
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80° F and maintain a voltage above 1.75 v/cell.
CA - Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell
MCA - Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell
HCA - Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 80° F at a voltage above 1.2 v/cell

The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development.
We reserve the right to change design, specifications, or pricing at any time without notice and without incurring obligation.




6 Volt Heavy Duty Commercial
BCI GROUP SIZE CENTENNIAL PART No. CCA RC minutes @ 25 amps CA / MCA HCA VOLTAGE LENGTH WIDTH HEIGHT
1 C-1 575 150 720 830 6 9 1/8 7 1/8 8 3/4
2 C-2 625 160 780 895 6 10 3/8 7 1/8 8 3/4
2E C-2E 615 185 770 885 6 9 7/16 4 1/8 9 1/8
3EH C-3EH 850 280 1065 1225 6 19 5/16 4 3/8 9 13/16
4 C-4 1000 310 1250 1440 6 13 1/8 7 1/8 9 3/8
4EH C-4EH 930 320 1165 1340 6 19 5/16 5 9 13/16
5D C-5D 850 280 1065 1225 6 13 3/4 7 1/8 9 3/8
7D C-7D 950 360 1190 1370 6 16 1/4 7 1/8 9 3/8

The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development and we reserve the right to change design, or specifications or pricing at any time, without notice and without incurring obligation.

CCA - Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0 degrees farenheit at a voltage above 1.2 v/cell
CA - Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell
MCA - Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell
HCA - Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80 degrees farenheit and maintain a voltage above 1.75 v/cell.



12 Volt Commercial Tractor
BCI GROUP SIZE CENTENNIAL PART No. CCA RC minutes @ 25 amps CA / MCA HCA VOLTAGE LENGTH WIDTH HEIGHT
3EE C-3EE 425 115 530 610 12 19 15/16 4 3/8 8 7/8
3ET C-3ET 460 120 575 660 12 19 5/16 4 3/8 9 13/16
4DLT C-4DLT 1000 240 1250 1440 12 20 8 3/16 7 15/16
16TF C-16TF 640 250 800 920 12 16 9/16 7 1/8 11 1/8
17TF C-17TF 510 120 640 735 12 17 1/16 6 15/16 7 15/16
22NF C-22NF 390 70 490 565 12 9 7/16 5 1/2 8 15/16
U1L C-U1L-4 190 30 240 275 12 7 3/4 5 3/16 7 5/16
U1R C-U1R-4 190 30 240 275 12 7 3/4 5 3/16 7 5/16
U1L C-U1L-5 250 35 315 360 12 7 3/4 5 3/16 7 5/16
U1R C-U1R-5 250 35 315 360 12 7 3/4 5 3/16 7 5/16
U1L C-U1L-6 330 40 415 475 12 7 3/4 5 3/16 7 5/16
U1R C-U1R-6 330 40 415 475 12 7 3/4 5 3/16 7 5/16

The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development and we reserve the right to change design, or specifications or pricing at any time, without notice and without incurring obligation.

CCA - Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0 degrees farenheit at a voltage above 1.2 v/cell
CA - Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell
MCA - Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell
HCA - Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80 degrees farenheit and maintain a voltage above 1.75 v/cell.